Current File : //usr/share/perl5/vendor_perl/Ocsinventory/Agent/Backend/OS/Linux/Storages/HP.pm
package Ocsinventory::Agent::Backend::OS::Linux::Storages::HP;

use Ocsinventory::Agent::Backend::OS::Linux::Storages;
# Tested on 2.6.* kernels
#
# Cards tested :
#
# Smart Array E200
#
# HP Array Configuration Utility CLI 7.85-18.0

use strict;

sub check {
    my $params = shift;
    my $common = $params->{common};

    my $ret;
    # Do we have ssacli ?
    if ($common->can_run("ssacli")) {
        foreach (`ssacli ctrl all show 2> /dev/null`) {
            if (/.*Slot\s(\d*).*/) {
                $ret = 1;
                last;
            }
        }
    }
    return $ret;

}

sub run {


    my $params = shift;
    my $common = $params->{common};
    my $logger = $params->{logger};

    my ($pd, $serialnumber, $model, $capacity, $firmware, $description, $media, $manufacturer);

    foreach (`ssacli ctrl all show 2> /dev/null`) {

    # Example output :
    #    
    # Smart Array E200 in Slot 2    (sn: PA6C90K9SUH1ZA)

        if (/.*Slot\s(\d*).*/) {
            my $slot = $1;
            foreach (`ssacli ctrl slot=$slot pd all show 2> /dev/null`) {
                # Example output :
                # Smart Array E200 in Slot 2
                #
                #   array A
                #
                #      physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SATA, 74.3 GB, OK)
                #      physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SATA, 74.3 GB, OK)
                if (/.*physicaldrive\s(\S*)/) {
                    my $pd = $1;
                    foreach (`ssacli ctrl slot=$slot pd $pd show 2> /dev/null`) {
                        # Example output :
                        #  
                        # Smart Array E200 in Slot 2
                        #
                        #   array A
                        #
                        #      physicaldrive 1:1
                        #         Port: 2I
                        #         Box: 1
                        #         Bay: 1
                        #         Status: OK
                        #         Drive Type: Data Drive
                        #         Interface Type: SATA
                        #         Size: 74.3 GB
                        #         Firmware Revision: 21.07QR4
                        #         Serial Number:      WD-WMANS1732855
                        #         Model: ATA     WDC WD740ADFD-00
                        #         SATA NCQ Capable: False
                        #         PHY Count: 1        
                        $model = $1 if /.*Model:\s(.*)/;
                        $description = $1 if /.*Interface Type:\s(.*)/;
                        $media = $1 if /.*Drive Type:\s(.*)/;
                        $capacity = $1 if /^\s*Size:\s(.*)/;
                        $serialnumber = $1 if /.*Serial Number:\s(.*)/;
                        $firmware = $1 if /.*Firmware Revision:\s(.*)/;
                    }
                    $serialnumber =~ s/^\s+//;
                    $model =~ s/^ATA\s+//; # ex: ATA     WDC WD740ADFD-00
                    $model =~ s/\s+/ /;
                    $manufacturer = Ocsinventory::Agent::Backend::OS::Linux::Storages::getManufacturer($model);
                    if ($media eq 'Data Drive') {
                        $media = 'HDD';
                        if ($description =~m/SSD|Solid State/) {
                            $media = 'SSD';
                        } elsif ($model =~m/SSD|Solid State|WDS/) {
                            $media = 'SSD';
                        }
                    }

                    if ($capacity =~m/TB/) {
                        $capacity *= 1000000;
                    } elsif ($capacity =~m/GB/) {
                        $capacity *= 1000;
                    } else {
                        $capacity *= 1;
                    }

                    $logger->debug("HP: N/A, $manufacturer, $model, $description, $media, $capacity, $serialnumber, $firmware");

                    $common->addStorages({
                            NAME => $model,
                            MANUFACTURER => $manufacturer,
                            MODEL => $model,
                            DESCRIPTION => $description,
                            TYPE => $media,
                            DISKSIZE => $capacity,
                            SERIALNUMBER => $serialnumber,
                            FIRMWARE => $firmware
                    }); 
                }
            }
        }
    }
}

1;